AquaGuard Magnetic Float Sensor and Tank Installation Guide Kathmandu
Plumber & Electrician Field Manual

AquaGuard IPC STAR PRO Installation & Wiring Guide

Zero-guesswork dual-tank float placement, Cat5/2-core low-voltage 12V DC routing, and external contactor schematics from 0.5 HP residential pumps to 50+ HP three-phase plants.

Live Technician Helpdesk
Field Wiring Summary: AquaGuard isolates tank wiring on a safe 12V DC sealed loop (`INV-FS-MG01`) completely separate from 230V/400V pump power. Pumps up to 0.5–5 HP single-phase wire directly (10 HP heavy-duty option available), while 5 HP to 50+ HP three-phase borewells connect via a 3-pole AC contactor coil without loading internal PCB relays.

4-Step Installation SOP (Kathmandu & Regional Sites)

Step Engineering Instruction Common Field Mistake Avoided
1. Enclosure PlacementMount vertically near pump starter panel indoors (max 50–100m float run using twisted pair cable).Never splice low-voltage 12V DC sensor cables inside the same conduit as high-amperage 3-phase motor wires.
2. Sump Dry-Run SensorAnchor bottom float ~15–20 cm above foot valve strainer in underground reserve tank.Mounting flat on floor picks up heavy silt; mounting too high causes premature dry-run trips.
3. Overhead Roof SensorFix upper float below roof overflow elbow; anchor refill trigger at ~30% remaining tank height.Keep sensors away from splashing inlet jets so false waves don't chatter relays.
4. Pump Power StageSingle-phase 0.5–5 HP direct/contactor; 5–50+ HP three-phase routes controller output to A1/A2 contactor coil.Protects PCB contacts on high-inrush borewell motors and preserves Star-Delta timing.

Need Valley turnkey installation? Book directly via AquaGuard IPC STAR PRO, plan multi-tank buildings at Commercial Water Systems, or register your 24-month controller & sensor warranty on Support & Warranty.