Engineering Support Hub

Support & Technical Resources
Datasheets, Warranty & Service RMA.

Official technical documentation, verified manufacturer specifications, 24-month controller warranty (24-month sensor warranty) services for AquaGuard, and laboratory RMA intake for industrial electronics across Nepal.

Verified Ground Truth

Official Product Datasheets & Technical Manuals

Direct access to manufacturer specification sheets, system dimensions, wiring guides, and operational manuals for all distributed equipment.

Flagship Control System Rev 2026.1

AquaGuard IPC STAR PRO

Comprehensive technical specification, terminal wiring diagram, voltage trip thresholds (170V–240V), and dual-tank waterproof DC sensor setup instructions.

Thermal Inkjet (TIJ) Dotjet Inc.

Dotjet DJ45plus Industrial TIJ

Official datasheet detailing HP TIJ 2.5 architecture, 7" capacitive display, Linux controller, MySQL protocol, and dual-head 25.4 mm print envelope.

Compact TIJ Dotjet Inc.

Dotjet DJ1 Compact Printer

Single-head (12.7 mm) aluminum casting housing specifications, 2.8" color LCD menu tree, 652g net weight parameters, and mounting arm engineering drawing.

Barcode & Label Zebra Tech

Zebra ZD230 Desktop Series

Official Zebra specification sheet identifying 203 DPI (8 dots/mm) resolution, up to 6 ips (152 mm/s) speed, 104 mm print width, and 300m ribbon capacity.

Continuous Inkjet (CIJ) Hitachi Japan

Hitachi UX Series CIJ (UX-B160W)

Hitachi Industrial Equipment Systems brochure detailing 65 μm nozzle parameters, 1,148 chars/s speed, 10.1" touchscreen interface, and IP55 enclosure protection.

Handheld & Inline TIJ Dailyjet

Dailyjet HP1000 & HP1200 Series

Technical specification sheet covering the HP1000 portable carton coder and HP1200 inline touch printer using 42ml HP 2.5 cartridges.

Industrial Surveillance Hikvision

Hikvision DS-2CD2143G2-I Series

AcuSense 4MP fixed dome technical specification sheet covering deep learning human/vehicle classification, 120 dB WDR, IP67 weatherproof, and IK10 vandal resistance.

Industry-Leading Coverage

AquaGuard IPC STAR PRO: 24-Month Controller & 24-Month Sensor Warranty

Nepal's only industrial water pump automation system backed by an uncompromising 24-Month Controller and 24-Month Sensor direct replacement guarantee.

The Invento Guarantee

Zero Downtime Replacement for Peace of Mind

We engineer AquaGuard IPC STAR PRO with heavy-duty automotive-grade relays and industrial microcontrollers. If your unit experiences a genuine circuit, telemetry, or auto-trip failure within 24 Months of purchase for the controller or 24 Months for the sealed 12V DC waterproof magnetic float sensors, we replace the faulty component or unit immediately.

Full Electrical & Logic Replacement

Covers relay contact welding, MCU lockup, voltage threshold calibration drift, and dry-run sensor failure.

Priority Laboratory Dispatch

Replacement units dispatched within 24 hours of receipt at our Kathmandu laboratory or authorized regional partners.

Extended Lifecycle Support

Even beyond the 24-Month warranty, our component-level lab repairs AquaGuard units at minimal component cost.

Warranty Verification Checklist

To ensure swift warranty validation, ensure you have the following information available:

  • Unit Serial Number (found on rear metallic label)
  • Date of Purchase & Dealer / Invoice Reference
  • Pump Horsepower & Operating Environment
  • Photo of Front Panel LED Status Indicators
Warranty Exclusions Direct lightning strike on ungrounded service lines, severe physical impact, or unauthorized board tampering.
Laboratory Service Intake

Industrial PCB & Drive/VFD Repair RMA Intake

Standardized intake procedure for factory electronics, industrial inverters, and automation controllers sent to our Kathmandu central laboratory.

1

Intake & Dispatch

Deliver faulty boards to our Baneshwor-10 lab or courier via regional transport. Include contact name, company, and detailed error codes.

2

Lab Diagnostics

Within 24 working-day hours (Sun–Fri), our engineers perform VI curve tracing, oscilloscope checks, and trace-level bench inspection to identify component failures.

3

Quotation & Repair

We issue a transparent quotation before replacing failed IGBTs, optocouplers, capacitors, or microcontrollers with genuine components.

4

Load Test & Warranty

Repaired units undergo full-load dynamometer or motor simulation testing and are returned with our repair warranty.

Printable Courier RMA Packing Slip

Courier Your Factory Boards Safely

Consignee: Invento Engineering and Consultant Pvt. Ltd. (PCB & VFD Lab)
Address: Sahabhagita Marga, Baneshwor-10, Kathmandu 44600, Nepal
Attn: Er. Krishna Shah (Lead Diagnostics)
Direct Contact: +977 9801511144 / +977 9849151615

Mandatory Box Packing Checklist:
1. Equipment Model & kW Rating (e.g., Delta VFD-E 7.5 kW / Hospital Centrifuge)
2. Visible Error Code / Trip Behavior (e.g., OC / OV / Dead Display)
3. Sender Factory Name, Contact Person & WhatsApp Number inside anti-static bag

Backed by a 90-Day Kathmandu Bench Repair Warranty across Pokhara, Biratnagar, Birgunj, Chitwan & Butwal dispatches.

Need Urgent Diagnostic Consultation?

Message our lead diagnostics engineer directly on WhatsApp with your board model and fault symptoms for an instant assessment.

Instant WhatsApp Consultation
Technical Knowledge Base

Frequently Asked Support Questions

Quick engineering answers regarding installation, pump telemetry, ink cartridge maintenance, and repair turnaround times.

How does AquaGuard protect pumps when voltage fluctuates in Nepal?

AquaGuard IPC STAR PRO features continuous micro-sampling of incoming utility power. If line voltage drops below 170V (causing high current and winding overheat) or rises above 240V, the controller auto-trips the motor instantly and recovers only when voltage normalizes for a stable duration.

What should I do if my thermal inkjet (TIJ) cartridge nozzles dry out?

For Dotjet or Dailyjet HP TIJ 2.5 cartridges, gently wipe the nozzle plate in one direction using a lint-free electronic wipe moistened with pure isopropyl alcohol (IPA). Never shake solvent cartridges aggressively. When not in use, always store cartridges in their sealed clip.

What is the typical turnaround time for VFD inverter repair?

Standard diagnostic evaluation is completed within 24 to 48 hours. Most component-level repairs (IGBT module replacement, gate driver repair, electrolytic bank recap) are finalized within 2 to 4 business days depending on OEM component availability in Kathmandu stock.

Can Invento provide on-site industrial machinery troubleshooting?

Yes. For industrial packaging lines, water bottling plants, and automated control panels, our field engineering team conducts on-site diagnostic visits throughout Kathmandu Valley and regional industrial corridors by scheduled consultation.

Need Further Engineering Assistance?

Our certified electronics and automation engineers are ready to answer your technical inquiries, provide wiring diagrams, or coordinate an emergency factory repair.

Request Client Support Download Datasheet WhatsApp Support Desk