Industrial Pump Controller 100% Unattended Logic Made in Nepal Electrical Automation Device (Not a Drinking Water Purifier)

AquaGuard IPC STAR PRO — Automatic Water Pump Controller in Nepal

Never Forget the Pump. Automatic, Fail-Safe Water Level Automation.

Turnkey packages starting at NPR 10,000 (+ taxes) (Includes IP54 indoor controller, dual-tank waterproof DC float sensors, Free Installation & 1-Year AMC)

Sub-2.0s dry-run lockout, voltage window protection (170V–240V AC), and isolated DC float sensors eliminate motor coil burnout and stop rooftop overflows across Nepal's municipal and boring well lines.

Entity Note for Searchers: Invento AquaGuard is an automated water motor switch and dry-run protector engineered in Nepal by Invento Engineering — not to be confused with Eureka Forbes drinking water filtration purifiers.
170V–240V AC Operating Voltage & Phase-Failure Protection
Sealed 12V DC Waterproof Magnetic Float Sensors: Zero Tank Corrosion or Scaling
Direct Drive up to 5 HP; Above 5 HP via External Contactor
24-Mo. Controller Warranty 24-Mo. Sensor + 1-Yr AMC
Free Turnkey Installation 2–4 Hr Retrofit (No Disruption)
Kathmandu Valley Support Within 24h Working-Day Response
System Telemetry Monitor
System Normal · Armed
Grid Voltage RMS 232 V 170V–240V Window OK
Motor Contactor Pumping Active · 0 Overload
Overhead Tank 84% Upper Standby Ready
Underground Sump 92% Ample Suction Head
Waterproof DC Float: Active
Sub-2.0s Dry-Run: Armed
Phase Lockout: Monitored
Restart Delay: 3-Min Intelligent
Hardware & Architecture Standard Model: IPC-STAR PRO
5 LED Indicators Bakelite Terminals
Up to 5 HP Direct >5 HP via Contactor
IP54 Indoor Unit 0°C–55°C Rated
The Operational Reality

Nepal's 4 Critical Water Infrastructure Failures

Every day, facilities across Kathmandu suffer expensive motor damage, wasted water tariffs, and structural degradation from unmanaged pump operations.

Failure Mode 01

Catastrophic Tank Overflow

Unmonitored rooftop tanks frequently overflow during manual pumping cycles, wasting thousands of liters of clean water. Cascading overflows seep into parapets and facades, accelerating concrete dampness, efflorescence, structural spalling, and electrical conduit deterioration.

High water tariff waste
Failure Mode 02

Dry-Run Motor Burnout

When municipal lines or underground sumps deplete mid-cycle, standard pumps run in air. Without fluid cooling, mechanical face seals disintegrate in under 90 seconds, followed by winding thermal runaway costing NRs. 4,000–7,500 per rewind (up to NRs. 25,000+ for complete motor replacement).

NRs. 4k–7.5k per rewind
Failure Mode 03

Severe Grid Voltage Sags (170V)

Nepal's electrical distribution network regularly dips down to 170V during peak evening draw. Single-phase induction motors draw over 40% higher amperage to maintain torque, melting enamel winding insulation within weeks of operation.

40% inductive current surge
Failure Mode 04

Human Manual Switching Error

Institutions and hotels delegate pump switching to security guards or caretakers. Inevitable human oversight results in empty tanks during morning guest peaks, forgotten pumps running all night, and erratic supply schedules.

Eradicate human dependence
Engineering Mechanism

Solid-State Sensing & Multi-Stage Motor Protection

Replacing failure-prone mechanical switches with sealed waterproof DC magnetic float sensors and solid-state interlocks.

How AquaGuard Eliminates Sensor Scaling & Motor Burnouts

Unlike conventional water controllers that pass electric current directly through water via conductive metal probes (triggering rapid mineral scaling, oxidation, and electrolysis within 3 months in Nepal's hard water), AquaGuard units ship with sealed 12V DC waterproof magnetic float sensors. Electrical contacts remain completely isolated inside an engineering polymer housing, ensuring zero liquid electrical contact, zero sensor scaling, 100% galvanic safety, and long running life without need of sensor maintenance.

1

Synchronous Dual-Tank State Logic

The microcontroller continuously samples the underground sump (source) and overhead rooftop tank (delivery). The motor starter coil is energized ONLY when the rooftop tank drops below 50% AND adequate positive head is confirmed in the underground reservoir.

2

True-RMS Line Voltage Sampling

Integrated analog-to-digital converters continuously sample grid voltage. If line voltage falls outside 170V–240V, the relay disengages the motor instantly. A built-in 3-minute stabilization delay prevents inductive switch bounce when grid power fluctuates.

3

Non-Volatile EEPROM State Memory

Internal EEPROM registers retain complete system state across blackouts and generator transfers. When power restores, operation resumes safely without false ignition or erratic cycling.

Interactive Hardware Simulator Live Firmware Model
INVENTO IPC STAR PRO SIMULATOR
Power
Overhead Full
Overhead 50%
Sump Source OK
Overhead Tank Level:
Underground Reservoir:
Simulated Line Voltage: 220V AC

Automatic Pumping

Pumping smoothly from source to overhead tank. Voltage is stable at 220V. 24/7 intelligent control active.

System Workflow

How AquaGuard Operates: 5-Stage Automation

Zero human intervention required. Precision closed-loop cycle from demand sensing to automatic power disengagement.

Stage 01

Dual-Level Sealed Sensing

Waterproof DC float sensors monitor water thresholds in sump & overhead tank simultaneously without liquid contact.

Stage 02

Logic Verification

Microcontroller verifies overhead demand AND ensures underground source has adequate water before firing.

Stage 03

Voltage Safety Check

True-RMS voltage sensor confirms grid line is within safe 170V–240V AC operating window before engaging pump motor.

Stage 04

Motor Ignition

Pilot relay triggers pump contactor smoothly without contact chatter or inductive voltage bounce.

Stage 05

Auto Cutoff

Instantly disengages pump upon full overhead level or dry-run, entering fail-safe standby.

Deterministic Reliability

Industrial Fail-Safe Architecture

Facility engineers and hospital administrators cannot rely on optimistic claims. Here is exactly what AquaGuard's solid-state logic executes when critical faults occur:

Scenario 01 · Sump Dry-Run

Source Water Depletion

Underground municipal reservoir or deep boring water drops below the safety threshold while pump is running.

Fail-Safe Action: Disengages contactor in < 2.0s before air can heat mechanical seals. Autonomous 3-min to 15-min recovery delay prevents pump stuttering.
Scenario 02 · Grid Sags & Surges

170V–240V Operating Voltage Protection

Protects pumps from undervoltage below 170V (causing heavy stator current draw) and overvoltage surges above 240V AC.

Fail-Safe Action: True-RMS line monitor trips pilot contactor in < 40ms. Auto-recovery engages ONLY after voltage remains stable for 3 continuous minutes.
Scenario 03 · Sensor Fault

Cable Cut / Open Circuit

Physical damage to float cables, pest chewing, or disconnected terminal during facility maintenance.

Fail-Safe Action: Circuit logic defaults to open-circuit SAFE STOP. The pump is isolated immediately—it will NEVER run wild or cause rooftop flooding.
Scenario 04 · Operational Control

Manual Facility Override

Routine tank descaling, plumbing line servicing, or urgent manual water transfer during maintenance windows.

Fail-Safe Action: 3-Position Industrial Selector (AUTO / OFF / MANUAL) allows technicians to run or lock out pumps without disconnecting control wiring.
Engineering Parameters

Technical Specifications & Parameters

Factory-calibrated specifications for residential, institutional, and heavy-duty industrial pumping infrastructure.

Operating Line Voltage 170V – 240V AC, 50Hz Operating Window
Motor Drive Rating Direct drive up to 5 HP | Above 5 HP (single-phase or 3-phase) via external magnetic contactor
Sensor Circuit Voltage 12V DC Intrinsically Safe Isolated Loop (Zero liquid electrification, zero electrolysis, safe to touch)
Pump Motor Compatibility Submersible deep-well pumps, Centrifugal monoblocks, Open-well, Jet pumps, Multi-stage booster systems, DOL, Star-Delta, VFD panels
Liquid Sensor Hardware Sealed 12V DC Waterproof Magnetic Float Sensors (Corrosion-resistant engineering polymer, zero liquid electrical contact)
Dry-Run Cutoff Response < 2.0 Seconds solid-state cutoff upon sump water dropping below suction threshold
Voltage Window Protection Operating Range: 170V – 240V AC | Automatic trip outside safe window | Re-engagement delay: 3 Minutes
Enclosure & Terminals Indoor Wall-Mount Unit (IP54 Enclosure) with Heavy-Duty Bakelite Terminal Connector Block
Physical Dimensions Height: 3 in × Width: 5 in × Thickness: 2 in (approx. 76 × 127 × 51 mm) | Wall Mount Flanges
Diagnostic Indicators 5 Panel LEDs: Power / Mains Indicator, Motor Run Indicator, Overhead Full, Reservoir OK, Overhead Half
Operation Logic Fully Automatic Microprocessor Control via Dual-Tank Float Sensors (Direct Up to 5 HP / Contactor >5 HP)
Operating Environment 0°C to 55°C | Indoor Dry Mount Installation
NPR 10,000 (+ taxes)
Complete Turnkey Package
Direct drive up to 5 HP (external contactor quoted above 5 HP). Includes IPC-STAR PRO controller + dual sealed 12V DC waterproof magnetic float sensors + professional installation + 1-Year AMC + 24-Month Controller Warranty & 24-Month Sensor Warranty.
Book Site Survey Request Full PDF Datasheet

Need custom Star-Delta, VFD, or multi-pump panel fabrication? Invento engineers build customized control boards.

Inquire for Custom Panel
Field-Ready Deployment

Turnkey Field Installation & Panel Integration

Engineered for seamless retrofitting into your existing motor starter panels without modifying existing plumbing or tearing down electrical infrastructure.

Starter Panel & Contactor Integration ≤5 HP Direct / >5 HP Contactor

Compatible with Direct-On-Line (DOL), Star-Delta, Soft-Starters, and VFDs from Schneider, L&T, ABB, Havells, and Siemens without disturbing factory wiring.

Non-Invasive Waterproof Float Routing 12V DC Galvanic Isolation

Heavy-duty waterproof DC float sensors hang suspended into reservoirs and sumps through inspection manholes. Zero tank wall drilling, zero pipe cuts, zero leakage risks.

Turnkey Installation by Invento Technicians Kathmandu Rapid SLA

Completed in 2 to 4 hours with live pumping validation, sub-2.0s dry-run trip testing, free turnkey installation, 1-Year AMC, 24-Month Controller Warranty, and 24-Month Sensor Warranty sign-off.

AquaGuard IPC-STAR PRO Turnkey Installation Architecture with Wall Controller, Cable Conduit Management, Digital Pressure Gauge, and Manifold Integration
Turnkey Retrofit Architecture · 100% Validated
IP54 Indoor Unit Bakelite terminal connector
Clean Wire Conduits Safety color-coded clips
Manifold Ready Inline hydro & filter friendly
Proven Financial ROI

Empirical Evidence & Financial Payback

AquaGuard eliminates overflow losses, reduces pumping electricity, and avoids expensive motor rewinds, delivering complete capital payback in approximately one year.

100% Overflow Waste Eliminated
0–30% Lower Power Consumption
NPR 4K–5K Saved per Avoided Rewind
~1 Year Average Capital Payback

Interactive ROI & Savings Estimator

Calculate direct daily and annual water and electricity savings based on Nepal's grid tariff and tanker water economics.

10,000 L / day
Home: 500–2,000L School: 10,000–15,000L Hotel/Hospital: 20,000–50,000L
2,000 L
Small: 1,000L Refill Frequency: 5 Cycles / Day Commercial: 20,000L
2.0 HP
0.5 HP (0.37 kW) 1.49 kW Draw · Tariff: NPR 13/kWh 10.0 HP (7.46 kW)

Dual Savings Breakdown (Day & Year)

Nepal Verified
Water Saved from Overflow: Eliminates 40–60L per missed switch-off
275 L / day
100,375 L / yr
Tanker Water Cost Saved: NPR 2,200 per 10,000L tanker rate
NPR 22,083 / yr
10.0 Tankers Saved
Pumping Electricity Saved: Standard tariff: NPR 13.00 / kWh
0.25 kWh / day
NPR 1,180 / yr (91 kWh)
Avoided Motor Rewind / Repair: Typical Nepal repair: NPR 4,000 (1 HP) · NPR 5,000 (2 HP) per burnout avoided
NPR 5,000 / incident
Total Annual Savings (Water & Electricity): Guaranteed utility savings from overflow & power cutoffs
NPR 23,263 / yr
Estimated Capital Payback Horizon: 5.7 Months
Base Pricing Guidance: Complete controller setups start from NPR 6,500 for standard residential dual-tank configurations. Final turnkey quote depends on sensor cable run length, pump horsepower, and site-specific panel requirements.

* Engineering Disclaimer: Total annual savings and capital payback are calculated strictly from direct water and electricity savings based on Nepal's grid tariff (NPR 13/kWh) and typical Kathmandu tanker rates. In addition, preventing a single dry-run or voltage sag burnout immediately avoids an unexpected motor rewinding bill of NPR 4,000 (1 HP) or NPR 5,000 (2 HP).

Proven Field Performance

Proven Deployments Across Nepal's Institutions

Commercial facilities trust AquaGuard to protect mission-critical water delivery and prevent costly equipment breakdowns.

Hospitality Sector · Thamel, Kathmandu

Hotel Thamel Park

Challenge: During peak tourist occupancy, manual caretaker switching led to repeated 2:00 AM roof overflows, flooded guest corridors, and expensive emergency tanker refills.
Solution: Deployed AquaGuard IPC-STAR PRO on dual 3.0 HP booster pumps with synchronized underground sump and rooftop interlocks.
Verified Outcome: 100% Zero Overflow Since Installation · 7+ Years Continuous Service
Academic Campus · Satdobato, Lalitpur

Moon Light Higher Secondary School

Challenge: Unmonitored overhead tank overflow during busy school hours caused chronic water loss and spiked monthly pumping electricity bills.
Solution: Deployed AquaGuard controller with 5-second wave debounce logic and automatic dual-tank level monitoring.
Verified Outcome: 3+ Years Continuous Reliable Pumping with Zero Overflow
NGO Head Office · Chakupat, Lalitpur

DZI Organization

Challenge: Required an automated, low-maintenance pump control system to eliminate manual caretaker error and sensor corrosion across head office facilities.
Solution: AquaGuard controller utilizing hermetically sealed waterproof DC magnetic float sensors for continuous unattended operation.
Verified Outcome: 3+ Years Flawless Uptime with Zero Sensor Maintenance
Verified Deployments

Real Production Units & Plant Room Installations

Zero mockups. Engineered, assembled, and deployed across Nepal's facilities.

Er. Krishna Shah, Founder & Lead Engineer at Invento Engineering Nepal

Er. Krishna Shah

Founder & Principal Engineer · Invento Engineering and Consultant Pvt. Ltd.

Electronics & Automation Engineer and founder of Invento Engineering (Estd. 2017). Passionate about solving everyday technical struggles for Nepal's schools, hospitals, and industries, he engineered the AquaGuard IPC-STAR PRO to eliminate motor burnouts, overcome 170V–240V grid power fluctuations, and safeguard vital water supplies with long-lasting digital reliability.

Electronics & Automation Expert Estd. 2017 Kathmandu In-House Hardware Lab Registered Pvt. Ltd.
Original Manufacturer Direct

Heavy-Duty Quality, Wholesale Supply & Nationwide Dealership

Invento Engineering is the original inventor and manufacturer of AquaGuard IPC STAR PRO in Kathmandu. Built with heavy-duty industrial relays, corrosion-proof waterproof DC magnetic float sensing, and dynamic 170V–240V AC voltage protection, our controllers serve plumbing contractors, hardware wholesalers, and institutional projects across all 7 provinces of Nepal.

10 to 25 Units

Contractor & Builder Pack

Engineered for MEP contractors, plumbing engineers, residential builders, and housing colonies across Nepal needing reliable dual-tank pump automation.

  • Heavy-duty 30A inrush industrial relay (0.5–5 HP direct)
  • Hermetically sealed waterproof DC magnetic float sensors
  • 170V–240V voltage guard & sub-2.0s dry-run cutoff
Request Contractor Pricing
Direct Manufacturer
50 to 100+ Units

Regional Wholesale & Dealership

For electrical wholesalers, sanitaryware showrooms, and hardware stockists in Kathmandu Valley, Pokhara, Biratnagar, Birgunj, Butwal, Narayangarh, Nepalgunj, and Dhangadhi.

  • Factory-direct dealer margins with full VAT invoicing
  • Protected city/district dealership & courier dispatch across 77 districts
  • 24-Month controller warranty & 24-Month sensor warranty backing
Apply for Nepal Dealership
Campus & Municipal

Institutional & Water Board Supply

Complete turnkey pump automation for hospitals, colleges, resort chains, industrial parks, and community drinking water projects (Khanepani Upabhokta Samiti).

  • External contactor integration for motors above 5 HP
  • Official tender technical documentation & VAT compliance
  • On-site commissioning & annual maintenance contracts
Request Institutional Quote
Clear Answers

Frequently Asked Questions

Everything facility directors, engineers, and building administrators need to know about AquaGuard IPC-STAR PRO.

How do waterproof DC float sensors prevent sensor corrosion and false readings?

Unlike conductive metal electrodes that pass electrical current directly through water—causing rapid mineral scaling, oxidation, and electrolysis—AquaGuard ships with hermetically sealed 12V DC waterproof magnetic float sensors. Electrical contacts remain completely isolated inside an engineering polymer housing, ensuring zero liquid electrical contact and long maintenance-free service life in Nepal's mineral-rich water.

Is AquaGuard IPC-STAR PRO compatible with both single-phase and three-phase pump motors?

Yes. AquaGuard directly drives pumps up to 5 HP, and supports higher-HP single-phase or three-phase motors above 5 HP via an external magnetic contactor, DOL, or Star-Delta starter. It includes comprehensive phase-loss and phase-reversal protection for three-phase installations.

How does the sub-2.0 second dry-run protection prevent motor burnout?

When an underground reservoir, municipal line, or boring well runs dry, the dedicated suction float sensor drops. AquaGuard's solid-state controller detects this threshold change and isolates the pump motor contactor in under 2.0 seconds, preventing mechanical seal melting and stator coil burnout.

Can AquaGuard be retrofitted into existing starter panels without modifying plumbing?

Yes. AquaGuard is engineered specifically for non-invasive retrofitting. Waterproof DC float sensors are suspended into tanks without drilling holes or cutting pipes. Invento engineers complete standard field installations in 2 to 4 hours with zero disruption to existing plumbing infrastructure.

What voltage protection does AquaGuard offer against Nepal's power fluctuations?

AquaGuard continuously monitors True-RMS line voltage every 20ms. It automatically disengages the motor when voltage moves outside the 170V–240V AC operating window (preventing undervoltage current overloads and surges). Once grid voltage stabilizes, an autonomous 3-minute recovery timer safely re-engages pumping.

What warranty and after-sales support does Invento Engineering provide in Nepal?

Every AquaGuard IPC-STAR PRO package includes Free Turnkey Installation and 1-Year AMC across Kathmandu Valley, a 24-Month Comprehensive Controller Warranty, and a 24-Month Sensor Warranty directly supported by Invento Engineering in Kathmandu. We maintain locally stocked spare parts and a dedicated field service team with rapid response across Kathmandu Valley.

What is the price of AquaGuard water motor automatic switch in Nepal?

Standard turnkey packages for the AquaGuard IPC-STAR PRO are NPR 10,000 (+ taxes). This complete package includes the IP54 indoor controller, dual-tank waterproof magnetic DC float sensors for both underground sump and overhead tanks, electrical wiring, 170V–240V protection, and on-site installation across Kathmandu Valley. Higher-HP motors above 5 HP requiring external contactors are quoted based on contactor capacity.

Can AquaGuard control single phase boring and 3-phase submersible motors?

Yes. AquaGuard is engineered to seamlessly operate with pumps directly up to 5 HP as well as higher-HP commercial single-phase and 3-phase motors above 5 HP through an external contactor integrated into existing Star-Delta, Direct-On-Line (DOL), or Variable Frequency Drive (VFD) starter cabinets. Built-in phase sequence and single-phasing protection prevents 3-phase motors from burning out if one electrical phase drops.

How does AquaGuard prevent motor burning when there is no water in boring or tank (dry run)?

In Nepal, deep boring wells and municipal sumps frequently run dry during dry season pumping. Conventional pumps continue running with empty impellers, causing water-lubricated bearings and stator windings to melt within minutes. AquaGuard monitors the suction reservoir in real time: the millisecond water levels fall below the safe suction threshold, the controller cuts motor power in under 2.0 seconds. It then enters an autonomous recovery standby mode, safely checking for water replenishment before restarting.

Does Invento provide installation and wiring service in Kathmandu, Lalitpur, and Bhaktapur?

Yes. Every AquaGuard purchase includes turnkey installation performed by Invento's certified electrical field engineers anywhere in Kathmandu, Lalitpur, and Bhaktapur. We handle panel retrofitting, neat conduit wiring, sensor positioning, and dynamic testing. The system includes a 24-Month Controller Warranty, 24-Month Sensor Warranty, and 1-Year on-site AMC support with within 24 working-day hours response service (Sun–Fri).

Direct Engineering Consultation

Schedule a Technical Consultation & Site Assessment

Eliminate overflowing tanks, dry-run stator burnout, and midnight pump operation. Consult directly with Invento's electrical engineering team to analyze your facility's pump layout, power parameters, and receive a customized turnkey quote.

On-Site Electrical Audit: Verification of starter panel compatibility (DOL, Star-Delta, or contactor retrofit).
True-RMS Voltage Assessment: Line voltage profile test under full starting surge.
Turnkey Package: Customized package with professional installation, 1-Year AMC, 24-Month Controller Warranty, and 24-Month Sensor Warranty.

Request Turnkey Site Survey

Direct dispatch to Er. Krishna Shah & Invento's field engineers.

By submitting this inquiry, you agree to our Privacy Policy regarding inquiry email delivery.